POWDERLA BRUKER D8-Vario and MTC oven X-ray Powder. POWDERSA BRUKER D8-Focus Bragg-Brentano X-ray Powder Diffractometer. The dual wavelength instrument is equipped with a MonoCap X-ray waveguide that increases the collimated Mo X-ray intensity by a factor of 2.5, an intense Cu IuS microsource, an APEX II charge-couple device (CCD) detector with ten-fold better sensitivity than first. The data were collected with Mo K ( 0.71073 Å) radiation at a crystal-to-detector distance of 50 mm using omega and phi scans. The Department of Chemistry at Vassar maintains an APEX2 DUO platform X-ray diffractometer from Bruker Advanced X-ray Solutions. QUEST ECO BRUKER-AXS Duo Mo Photon III 3-thircle X-ray Diffractometer. A Bruker Apex Duo diffractometer with an Oxford Instruments Cryojet running at 100 (2) K and an Incoatec micro source working at 30 W power was used to evaluate and collect data of L b.

APEX22 BRUKER-AXS Duo Mo/Cu micro-source APEX-II CCD 3-thircle X-ray Diffractometer. An equant crystal of saranchinaite was mounted on a Bruker APEX II DUO X-ray diffractometer operated at 50 kV and 40 mA and equipped with a micro-focus X-ray tube with an Mo anode at the Department of Crystallography, St. ** Academic institutions should contact Dr. APEX21 BRUKER-AXS APEX-II CCD 3-thircle X-ray Diffractometer. Single Crystal Data Collection & Structure University of Akron Departments In such cases the name of the responsible crystallographer will be included. Policy: There will be a policy of co-authorship in all publications that present collected and solved structures. Users who publish papers including data collected on the Bruker APEX II Duo system should include the following statement: We would like to acknowledge the National ScienceFoundation (CHE-0840446) for funds used to purchase the Bruker APEX II Duo X-ray diffractometer used in this research. Meetings and Consultations by Appointments onlyĪcknowledgments: Users who publish papers including data collected on the Bruker SMART APEX I system should include the following statement: We would like to acknowledge the National ScienceFoundation (CHE-0116041) and the Ohio Board of Regents for funds used to purchase the Bruker-Nonius Apex CCD X-ray diffractometer used in this research. Recrystallization for optimal data analysis Consultation for the best approaches of generating good diffraction crystals for data collection.
BRUKER APEX DUO SERIES
Data were collected in a series of and scans in 1.0o oscillations with a combination of 20.0 and 60.0-second. The data were collected at a temperature of -183.0 + 0.1oC to a maximum 2 value of 132.1o. Collecting, and mounting of water, temperature, air, and light sensitive crystals All measurements were made on a Bruker APEX DUO diffractometer with graphite monochromated Cu-K radiation.Data Collection, processing and analysis, including graphical presentations of structures.Our instrument is a Bruker Apex II Duo system with co-mounted Mo and Cu microfocus radiation sources.

The X-ray Center at The University of Akron is a state of the art facility capable of collecting high quality X-ray diffraction data on both small molecule and macromolecular crystalline samples.